9. Combined Building Services
9.1 Legend
Drainage
| vent pipe | |
| flat grating rain water outlet / floor drain | |
| soil waste pipe | |
| waste pipe | |
| rainwater pipe |
Electrical Services
| recessed mount speaker unit | |
| recessed typedown light c/w 1x18W PLC lamp, high pripority aluminium and anodized reflector, with matt silvery finishing control gearsm capacitors and all necessary accessories | |
| track light c/w ceiling mounted light track, 120W par 36 lamp, UVA reduction filter, silver mirror reflector, white-coloured housing, integral 2A fuse, protection glass and all necessary accessories | |
| 1200mm ceiling mounted fluorescent lighting fitting c/w 1x16W energy saving tubes, control gears HPF capacitor and all necessary accessories | |
| same as the above c/w 2z16W energy saving tubes | |
| exit sign plate, maintained type, c/w 1x18W fluorescent tube, clear aracrylic sheet, integral control gear and all necessary accessories | |
| cable link box | |
| 10A 1-way SP lightings switch at 1350 AFFLunless otherwise specified ( n stands for number of switches ) | |
| SPN/TPN isolator wall mounted type | |
| 13A single socket outlet at 300 AFFL unless otherwise specified | |
| junction box for speaker at 2900 AFFL | |
| junction box for slide projector | |
| junction box for video projectror at false ceiling | |
| junction box for microphone outlet at 300 AFFL | |
| junction box for theatre commander at floor level | |
| 13A twin socket outlet at 300 AFFL unless otherwise specified | |
| 13A switch fused connection unit above false ceiling unless otherwise specified | |
| 1 no. of 25mm concealed conduit inside false ceiling unless otherwise specified |
Fire Services
Wet system
| pendent sprinkler head under structure slab ( in wet system ) | |
| pendent sprinkler head under structure slab ( in dry system ) | |
| pendent concealed type sprinkler head ( in wet system ) | |
| pendent concealed type sprinkler head ( in dry system ) |
Dry system
| 200mm weatherproof fire alarm bell | |
| smoke detector under structure slab | |
| heat detector under structure slab | |
| fixed fire pump control panel | |
| f.s. transfer pump control panel | |
| sprinkler pump control panel | |
| dry contracts for generator running / failure indication ( by electrical sub-contractors ) | |
| audible / visual warning unit | |
| fixed fire pump | |
| f.s. transfer pump | |
| sprinkler jockey pump | |
| f.s. jockey pump |
Mechanical Services
Air side legend
| supply / primary / fresh air duct to / from above | |
| duct set up | |
| duct set down | |
| air filter | |
| linear grille / diffuser |
Water side legend
| water pump | |
| duct electric heater | |
| axial fan / in-line centrifugal | |
| propeller fan | |
| motor control centre |
Electrical legend
| 13A fused spur unit sub-contractor |
Air side abbreviations
| exhaust air duct | |
| supply air duct | |
| return air duct | |
| exhaust air fan | |
| transfer air fan |
Plumbling Services
Faucet
| pillar tap |
Piping
| city water pipe | |
| hot water pipe | |
| hot water return pipe | |
| flush water pipe | |
| vent pipe |
Fittings
| water meter | |
| gate valve | |
| drain valve | |
| rail valve | |
| Y-type strainer |
General abbreviations
| from above | |
| from below | |
| to above | |
| to below | |
| high level | |
| lown level |